Sunday, 2 October 2011

RIBA Stirling Prize 2011...and the winner is...


Congratulations to Zaha Hadid Architects.


The Evelyn Grace Academy, a cutting-edge new secondary school in Brixton, south London by Zaha Hadid Architects has won the prestigious £20,000 RIBA Stirling Prize 2011 for the best new European building built or designed in the United Kingdom.




















Friday, 30 September 2011

Harpenden...

Project in Harpenden, now prepared and ready for submission to planning.


Tuesday, 27 September 2011

ecoShowcase...

Bringing together: 
Major suppliers of sustainable and environmentally friendly building products (materials) to an online event, where you can: compare solutions and suppliers in our directory; register for a live ecoSHOWCASE event; read the latest product news and case studies
Events will be taking part over the next nine months.










Birmingham 11 Oct 11

Cardiff 18 Oct 11
Luton 8 Nov 11

Monday, 26 September 2011

Farm Development...

Planning has this week been granted for an Office, Stores, Workshop, Stables and Tack Room near Whimple in East Devon. Replacing an existing structure that is in a state of disrepair, this new development closes an existing yard with a timber framed building that will blend in well with the green surroundings.



Thursday, 22 September 2011

Student Accommodation...

Following the success in obtaining planning consent , drawings have now been prepared for a submission to Exeter City Council Building Regulations Department for the construction of student accommodation that will comprise of 12 student rooms, each with en-suite facilities together with communal living, dining / kitchen areas and outside amenity area. The site was appraised, having regard to its position in relation to the proximity of the City Centre and easy access to the University of Exeter Streatham Campus and the St Luke’s Campus. The 4-storey building is to enhance the street scene and be sympathetic to the buildings that surround the site and the St David’s Conservation Area.


This infill site had been in existence since 1782 and the site occupied by The Papermakers Arms Public House when the dwelling house was converted in 1814. Latterly the premises became known as the Papermakers, a Mex-Tex restaurant-pub until demolished in 2004. The developer, 'Exeter Land Developments Limited', are hoping to start on site in the very near future.




Lego Architecture...

I applaud  the fact that Lego have created a range of models for us bigger kids that portray famous buildings and structures from around the world. However, I do happen to think that they have got this one completely wrong...back to the drawing board Lego, maybe at Taliesin West!
(photohraph by Richard Anderson)

Wednesday, 7 September 2011

Manor House Phase 2 Demolition....











This week has seen the partial demolition of the existing adjoining outbuilding, retaining the original cob wall to the street side. Rebuilding work will soon start to create a rear entrance, utility, shower room and gymnasium under a thatched roof.

Tuesday, 30 August 2011

Residential Refurbishment & Extension, Crazelowman: Update...






















Re-roofing works are almost complete on the grade II 16th Century former farmhouse, replacing the corrugated asbestos sheet roofing with natural slate.


















The refurbishment will address the usual aspects associated with modernisation of older properties and the extensions are to comprise single storey mono-pitched additions, creating a new hallway; w.c.; utility room and family room. A new opening is to be created in the flank cob wall to provide ease of access to the family room and aid circulation to the ground floor layout.

Manor Update...
































Phase one continues with the third of four dormers now being framed out as well as first fix electrical and mechanical. Phase two is really picking up pace with the removal of the existing roof to the outbuildings.

Costs fall to build green homes...

Building Design Online are today reporting that:

A government report into building green homes has revealed that the cost of meeting sustainability codes has fallen in the past three years.
Produced by the communities and local government department, the research shows that average extra costs for homes built to code level 3 have fallen by three-quarters from £4,458 in 2008 to £1,128 last year.
Sustainable homes code were introduced back in 2007 and made it mandatory that all new housing meet code level 3 from the following May. All new homes are expected to be zero carbon from 2016.
The boss of the UK Green Building Council, Paul King, hailed the performance of the building industry in slashing the costs of going green.
“The industry has responded in a remarkable way,” he added. “Both house builders in terms of the design of new homes and the construction products industry in terms of the technology required.”
by David Rogers 

Sunday, 28 August 2011

100% Design...






Another show in town....
Looking for the latest design-led products for residential, commercial or retail applications? In search of inspiration? Dreaming of a one-stop-shop for industry professionals and design lovers? Put 22-25 September 2011 in your calendar now...100% Design is aimed at design and architectural industry professionals. Students can also attend on the Saturday and Sunday with the general public able to visit on the Sunday only.Your entry badge will give you unlimited access to all three shows (100% Design, 100% Futures and 100% Materials). Entry is free to trade and press visitors who register online no later than 16th September. 


Saturday, 27 August 2011

World Architecture Festival 2011...











The World Architecture Festival is taking place at Barcelona’s flagship convention centre, the Centro de Convenciones Internacionales de Barcelona, (CCIB). Held between the 2nd and 4th November 2011m the World Architecture Festival is the world’s largest, live, truely inclusive and interactive global architectural awards programme. It is a unique meeting point for Architects, suppliers and clients, attracting hundreds of entries and visitors from all over the world.

Be warned though, a single 3-day pass costs € 495...once you have journeyed to Spain and found accommodation.....I won't be attending.

Thursday, 25 August 2011

The London Design Festival 2011...


17-25th September, Nine amazing days of design events showcasing the UK's world-class creative community. If you're in town, well worth a visit.

Wednesday, 24 August 2011

Plans for new Apple HQ, by Norman Foster, officially released...


Colour...


Now that we're in to the second half of 2011 thought I'd just remind folk about this year's colour of the year.

50 Years of London Architecture...

RIBA Stirling Prize shortlist 2011...




The sun rises in the East...







The offices of Eastern Concrete are officially open. Guests at the informal launch included colleagues from Reimer in Canada, Scania (Great Britain) Limited as well as the design team. There are some external matters still to address, such as the rainscreen cladding, guarding to the balcony and signage, all of which is due  to be completed in the next few months.

Tuesday, 23 August 2011

The use of downlighters in dwellings – A Designers Guide...


Introduction
The use of downlighters is becoming increasingly common in dwellings and domestic extensions. This fact combined with recent amendments to the Building Regulations has prompted debate on their compliance between Building Control Surveyors and other construction professionals.

Fire Safety
Approved Document B of the Building Regulations includes requirements that floors in dwellings achieve a fire rating. This is normally 30 minutes for low rise buildings where the floor is not a compartment floor. When installing downlighters in such a floor, the question arises as to whether or not they will adversely affect its fire resistant properties to the extent that it will not comply.

Whilst there is not a great deal of research information available on this subject, tests sponsored by the DETR (now ODPM) and carried out by The Timber Research and Development Association (Trada Technology Report 1/2001) provide useful guidance. The view of many Building Control professionals is that additional protection in the form of intumescent covers, boxing or fire resisting fittings is a  necessary provision in all cases. It may be that these opinions that have been influenced by commercially driven advice from companies dealing in such products. It is important that our decisions are based on sound and independent scientific research, it being all too easy to ask for a higher standard knowing that we are unlikely to be challenged.

The above tests were carried out on typical timber joisted floors (measuring 3.2m x 4.2m) fitted with up to 24 plastic and metal clipped fittings of various diameters. All indicated that the unprotected downlighters did not cause premature failures in terms of load bearing capacity, insulation or integrity. It could be argued that such ‘laboratory’ standards do not represent a floor after the retrospective removal of areas of floor decking. Such concerns are weakened by the fact that patched areas are inevitably supported on noggins or joists and the tests included decking that was not tongued and grooved.

Similar tests on 60 minute fire resisting floors also did not show premature failure. This small scale evidence is sufficient to negate the need for downlighter protection in 60minute floors. Full scale evidence may be more onerous so in the absence of such information, covers should be provided.

It is also important that these tests are not seen as being representative of other floor types such as those incorporating engineered ‘I beam’ joists. Such members have little ‘sacrificial’ timber so rely almost entirely on the integrity of the ceiling lining to prevent failure in fire. Protective measures are also essential in this type of floor.


Sound Insulation
Internal floors within dwellings
When amended Part E hit our desks in July 2003, it bought into effect new controls on floor construction within dwellings in addition to the existing requirements concerning separating floors. This has caused surveyors to consider the impact of downlighter installation in such floors and whether the 40 R w dB sound insulation value would still be achievable. Acoustically rated fittings are available but are they necessary?

The advice from experienced acoustic consultants is that their effect on sound insulation properties is relatively negligible. Previous tests would suggest a reduction of only 1 – 2 dB. In view of the popularity of such fittings it would seem a reasonable approach to allow them in internal floors without any additional measures.

Separating floors between dwellings
The use of downlighters in various separating floor constructions is covered in the Robust Details Guide. This states that there should be a minimum ceiling void of 75mm and that; -
a) They should be fitted in accordance with manufacturers recommendations,
b) At centres not less than 75mm, and
c) Openings in the lining should not exceed 100mm diameter or 100 x 100mm square.

Developers who opt to register accordance with a robust detail should not deviate from this associated guidance. For separating floors not covered by robust details it would seem sensible to advise against their use. There is little relevant commentary in the Approved Document and such penetrations may well be the cause of failure in the necessary pre completion testing.

Thermal Insulation
Cold bridging
A common sight for surveyors carrying out final inspections of extensions and new dwellings is a roof space insulated with 250mm thick mineral wool quilt and with countless uninsulated patches around the downlighter fittings in the ceilings. The cumulative effect of this in terms of heat loss can be substantial.

It is true to say that most turn a blind eye to such cold bridges despite their contravention of Regulation L.1. This is because of the need to vent heat away from the units as per manufacturer’s advice. A more favourable arrangement can be achieved using downlighter bulbs that mainly direct heat downwards with far less heat production above the unit. This allows a small pocket in insulation to safely accommodate the fitting i.e. the omission of a small area of lower layer quilt in 2 layer systems. Consequently heat loss can be greatly reduced and Surveyors can confidently ensure compliance with the Regulations.

Efficient Lighting
Approved Document L 2006 edition amends the requirements for the provision of energy efficient lights. New dwellings for example now require 25% of all light fittings to be energy efficient ones. Compact fluorescent & LED downlighters are now available which meet this standard.

Access statements in demonstrating compliance with Part M of the Building Regulations: Access to and Use of Buildings – A Designers Guide...


Introduction
The new Part M of the Building regulations came into effect on 1 May 2004 introducing a revised set of rules relating to buildings other than dwellings. An amended Approved Document covering these changes suggests various ways of achieving compliance with the core requirements and in the majority of cases the designer will choose to accord with these recommendations or the similar guidance contained in the British Standard Code of Practice B.S.8300: 2001. This is not mandatory however as these documents only show one way in which to comply and there may be other equally satisfactory ways in which the requirements can be met. The new Part M also introduces the concept of an Access Statement.

Purpose of an Access Statement
Alternative solutions to access problems will vary depending on the intended use of a building and its size and location. The gradient of the plot will also have an influence. Changes of use and extensions to existing buildings can pose problems particularly if they are of architectural or historic importance. The purpose of an Access Statement is to allow a designer to outline their philosophy and approach to achieving a reasonable level of accessibility. In its simplest form this may be a confirmation that they intend to accord fully with the guidance contained in either Approved Document M or B.S.8300. In this case the specifications and drawings submitted with the Building Regulations application should demonstrate this.

Access Statements and Planning Applications
Ideally the designer should prepare a statement for submission with the Planning application and indeed the Office of the Deputy Prime Minister considers this good practice. It can then be  developed further for the Building Regulations application and during the construction process. This will provide the building owner with a useful document when considering compliance with the Disability Discrimination Act. The early consideration of such matters is advantageous in that any potential problems can be considered and resolved before any detailed design work takes place. It also avoids the need to seek amendments to planning consents where such problems only come to light at the Building Regulations stage.

Non-conformity with Usual Design Guidance
For designs that deviate from the usual design guidance, the Access Statement provides an opportunity to bring the Building Control Surveyor’s attention to this fact and to explain and justify that reasonable provision for accessibility has been made in other ways. The designer may wish to adopt more innovative methods or it may be that the normal provisions are not feasible for reasons of security, safety or conservation. With existing buildings undergoing extension or change of use, there may be complications caused by the existing structure or a need to conserve important architectural features. In all the above cases the designer needs to demonstrate achievement a reasonable provision or an equivalent or better level.

Further guidance on Access Statements and related matters can be found in Approved Document M (Para 0.20) and on the Disability Rights Commission website at drc-gb.org.